MJR Vision MJR Vision Vision & controls
retrofits
Home

Products

Camera Matching & Barcode Verification Pharmaceutical Literature Inspection System Pharma Retrofit Tiers Inkjet Address & Print Add-On Norwix Marking Systems Integration Legacy Electronics & PLC Controls Retrofit

Company

Case Studies About Contact

Product 02 · Pharmaceutical literature

PFIS — Pharma Folding Inspection System

The module order is Hugger Module, then the patented Curing Module, then the Inspection Control Unit (ICU). The inspection uses a bottom belt only, with two AI cameras and no top belt. The cameras check for unglued leaflets, skewed folds, and overlap or underlap at the top and bottom of the booklet. Sold whole or as separate modules.

The Hugger module squares the leaflet after the knife folder applies glue, while the glue is still wet. It can run independently of the inspection system. Zoom
The Hugger module squares the leaflet after the knife folder applies glue, while the glue is still wet. It can run independently of the inspection system.

Process

Hugger Module → Curing Module → Inspection Control Unit

Module 01

Hugger Module

Squares the leaflet after the knife folder applies glue, while the glue is still wet. The Hugger can run independently of the inspection system.

Module 02

Curing Module (patented)

Holds outserts under pressure for several minutes so the pressure-sensitive fold glue fully sets before anything is inspected.

Module 03

Inspection Control Unit (ICU)

Bottom belt only, with two AI cameras and no top belt. The cameras check every piece for unglued leaflets, a skewed fold, and overlap or underlap at the top and bottom of the folded booklet. The fold stays visible, so a failed glue bond shows itself.

The patented Curing Module. Zoom
The patented Curing Module.
The Inspection Control Unit (ICU). Zoom
The Inspection Control Unit (ICU).

The key difference

If the glue didn't hold, the outsert tells on itself.

Because only the bottom belt holds the piece, the fold remains visible to the cameras. An outsert whose glue did not hold physically springs open and sits taller on the belt — and that physical signal is what triggers automatic rejection.

Competing systems transport the piece between a top and bottom belt. That clamping blocks camera access to the fold, so those systems can only confirm that glue was injected — never whether it actually holds the fold shut.

Side by side

MJR vs. a typical top-and-bottom-belt system

 MJR Literature InspectionTypical top-and-bottom-belt system
TransportBottom belt only — fold stays exposedTop and bottom belts clamp the piece
Camera access to the foldUnobstructed, two AI camerasBlocked by the top belt
What is actually verifiedWhether the fold is holding shutOnly that glue was injected
Reject mechanismA failed outsert springs open, sits taller on the belt, and is automatically rejectedNo physical signal available — a failed bond can pass
Glue set before inspectionPatented curing module holds pieces under pressure for several minutes firstInspection without a dedicated curing stage
Barcode print & verifyIntegrated single-pen inkjet barcode print, with a third camera that verifies the printed barcode qualityTypically a separate add-on

Barcode reading & print verification

Add the MJR Z-Camera System.

PFIS’s third camera verifies the quality of the barcode printed by its single-pen inkjet. For more, add the MJR Z-Camera System, the highest-capability of our three Pharma Retrofit Tiers. In this application it reads the barcode and detects print by counting pixels, with dual live views on a PC-based touchscreen monitor, and it can be configured for much more.

Compare the Pharma Retrofit Tiers

MJR Z-Camera System with dual live views on a PC-based touchscreen monitor. Zoom
MJR Z-Camera System with dual live views on a PC-based touchscreen monitor.

The Hugger module

Squares the leaflet while the glue is still wet.

The Hugger module squares the leaflet after the knife folder applies glue, while the glue is still wet. It can run independently of the inspection system.

The Hugger module running The Hugger module squares the leaflet after the knife folder applies glue, while the glue is still wet. Here it runs independently of the inspection system.

Video

The system running end to end.

MJR PFIS — Pharma Folding Inspection System.

Next step

Send us the make and model of your line.

We will tell you what can be retrofitted, what it takes, and how fast. Parts lead time runs from immediate to about two weeks; once parts are on hand, installs are typically completed in one day.